Quality Control

All Employees are made aware of the company's quality policy to guarantee that it is understood, and that full commitment to it is essential.

The Quality Representative is responsible for ensuring that the requirements of the declared system are implemented and maintained.

* Parts are opened in an ESD/MSD compliant area for inspection of the actual items:
· MSD tab is checked for moisture intrusions, if necessary parts will be baked and resealed at an approved test house (certification of this process provided).
· Date code inconsistencies are checked.
· The markings on the part are checked for authenticity.
· Leads are inspected by hand held devices and by microscope if deemed necessary.


* If any issues are identified TCX has the following options:
· Reject parts immediately and contact our vendor for an RMA.
· Send parts to be 'de-lidded' (destructive physical analysis or DPA) for an inspection of the die and internal wiring.
· Send parts to a certified test house to be tested for for solderability and functionality.